"System Error 53 Has Occurred" Using Windows NT Load Balancing ServiceID: Q192466
|
When using WLBS' NBT support to scale the performance of Windows NT read-only file access and printing, attempts to use the Microsoft network
commands, such as net view and net use, fail with the following error:
System error 53 has occurred. The network path was not found.
This error can be caused by one of the following:
To resolve this issue, do one of the following according to which of the
above causes is relevant:
The cluster's system name, which is the first portion of the full Internet
name, must be a known NetBIOS computer name for NetBIOS to resolve it into
an IP address.
Because NetBIOS uses only the first IP address, the cluster IP address must
be listed first. Note that WLBS' NBT support cannot be used in single
NIC configurations because the dedicated IP address is always listed first
when a single NIC is used.
Additional query words: WLBS Convoy