Access Violation When Configuring a Printer from a MAC Client

ID: Q167418


The information in this article applies to:


SYMPTOMS

When a Macintosh client configures a printer from a Microsoft Windows NT Server computer and the printer is using the Lexmark TCP/IP Port Monitor, the following error occurs:

An application error has occurred and an application error log is being generated.
Spoolss.exe

Exception: access violation (0xc0000005), Address: 059d853ee
NOTE: The address value you receive may be different.


CAUSE

The resulting error message is the following:

Application exception occurred:
App: exe\spoolss.dbg (pid=196)
When: 4/8/1997 @ 17:26:13.234
Exception number: c0000005 (access violation)


RESOLUTION

The problem described earlier in this article has been resolved in the latest version of the Lexmark TCP/IP Port Monitor. This product is available through the Lexmark Technical Support Center at 1-606-232-3000. The file modified is Lexlmpm.dll.


MORE INFORMATION

MarkVision is manufactured by Lexmark International, a vendor independent of Microsoft; we make no warranty, implied or otherwise, regarding this product's performance or reliability.

Additional query words: prodnt ntmac watson sfm


Keywords          : kb3rdparty ntprint NTSrv 
Version           : WinNT:4.0
Platform          : winnt 
Issue type        : 

Last Reviewed: February 16, 1999