Cluster Server Returns SCSI Port Errors After Installing Service Pack 3ID: Q219428
|
After you install Windows NT 4.0 Service Pack 3 (SP3) on a computer with an Adaptec 78xx SCSI controller installed, one or more of the following Event IDs may be displayed in your System Event log.
This behavior occurs because the Adaptec 78xx SCSI driver version 4.0.1433.1 may have been overwritten by version 2 drivers from Service Pack 3 for the follwing SCSI cards:
To resolve this problem, reapply the latest driver for your Adaptec 290x, 291X, 294x, 394x, or 4944 SCSI card after you apply SP3. If you are just adding a new controller, verify proper termination per manufacturer specifications.
The third-party contact information included in this article is provided
to help you find the technical support you need. This contact information
is subject to change without notice. Microsoft in no way guarantees the
accuracy of this third-party contact information.
For additional information, please see the following article in the Microsoft Knowledge Base:
Q154690 How to Troubleshoot Event 9 and 11 Error Messages
You may also visit Adaptec's Web site:
http://www.adaptec.com/
Additional query words:
Keywords :
Version : winnt:4.0,4.0 SP3
Platform : winnt
Issue type : kbprb