Compex PNP NE2000 Compitable NIC May Cause Event ID 7000ID: Q173537
|
If you install Windows NT on a computer using the Compex NE2000-compatible
network interface card (NIC), the network may not start and the system
event log may contain the following error message:
Event ID: 7000
Source : Service Control Manager
Description: A device attached to the system is not functioning.
The default configuration for the Compex NE2000-compatible adapter is for Plug and Play functionality. For proper operation with Windows NT, the Compex NE2000 must use explicit configuration settings.
To work around this problem, use the MS-DOS setup utilities that come with the adapter to disable the Plug and Play setting. Set the card to an available IRQ and base I/O address, then remove and reinstall the Windows NT network adapter driver.
The third-party product discussed here is manufactured by a vendor independent of Microsoft; we make no warranty, implied or otherwise, regarding the product's performance or reliability.
Additional query words: PNP
Keywords : kberrmsg kbhw kbnetwork kbsetup ntsetup nthw ntconfig NTSrvWkst
Version : WinNT:4.0