Err Msg: "STOP 0x00000079 MISMATCHED_HAL" on IBM PC Server 320ID: Q148975
|
When you run Windows NT Setup on a multiprocessor IBM PC Server 320, it
stops during the second Setup disk, just after loading the keyboard driver
and the file allocation table (FAT) file system. The following Stop message
appears:
STOP 0x00000079 MISMATCHED_HAL.
The manufacturer-supplied hardware abstraction layer (HAL) must be manually
specified. At the beginning of the first Setup disk, when Setup displays
"Setup is Inspecting Hardware," press F5. After a while, a message will
come up saying that Setup could not detect your computer type, or that you
chose to specify the computer type. Select Other and put in the OEM-
supplied disk containing the HAL (in this case, the IBM device driver
disk). Select the only HAL presented and continue.
This computer also comes with a SCSI II Fast Wide PCI RAID controller for
which the driver must be manually installed. Choose Custom Install
instead of Express Install. At the Mass Storage Detection section,
type ESC to skip detection and manually specify the controller. Select
Other and then select the IBM-supplied RAID driver disk.
Additional query words: bluescreen
Keywords :
Version : 3.50 3.51
Platform : WINDOWS
Issue type :
Last Reviewed: February 11, 1999