READ_REGISTER_ULONG Doesn't Preserve ULONG Semantics on AlphaID: Q160610
|
The READ_REGISTER_ULONG routine in the HAL for Alpha platform computers does not preserve the ULONG semantics, which may cause the computer to stop responding or bugcheck.
Currently, the READ_REGISTER_ULONG routing explicitly zeros out the upper four bytes of the return value. This will destroy ULONG semantics, where bit 31 is sign extended through to bit 63. This will potentially cause drivers that poke memory mapped I/O for expected signatures to fail when comparing the return value of READ_REGISTER_ULONG to a static constant when bit 31 of the constant is set.
Microsoft has confirmed this to be a problem in Microsoft Windows NT
version 4.0.
This problem was corrected in the latest Microsoft Windows NT 4.0 U.S.
Service Pack. For information on obtaining the service pack, query on the
following word in the Microsoft Knowledge Base (without the spaces):
S E R V P A C K
Additional query words: prodnt alpha
Keywords : kbhw kbbug4.00 kbfix4.00.sp2 NTSrvWkst
Version : 4.0
Platform : winnt
Issue type :
Last Reviewed: February 2, 1999