ID: Q182834
The information in this article applies to:
Error messages developed in the recording component of a Diagnostic Capture Remote Environment (RE) are not currently logged in the Windows NT Event Log. Consequently, information gathered about the encountered error is lost.
The example detailed in the "More Information" section describes only one instance of this problem.
Microsoft has confirmed this to be a problem in Microsoft COM Transaction Integrator for CICS and IMS version 1.0. This problem was corrected in the latest SNA Server version 4.0 U.S. Service Pack. For information on obtaining this Service Pack, query on the following word in the Microsoft Knowledge Base (without the spaces):
   S E R V P A C K
The following is an actual example. It includes the additional information that you would expect to be written in the Event Log for this specific example.
First, create the error situation using the CedarBank tutorial as a basis.
1. Start Microsoft Management Console (MMC) and open the COM Transaction
   Integrator snap-in.
3. Click Diagnostic Capture and then click OK.
4. In the Capture Remote Environment Wizard, select CICS LINK as the type
   of RE, and then click Next.
6. Provide your own name for the Diagnostic Capture RE and click Next.
7. Click Finish.
8. In the left pane of MMC, right-click the new Diagnostic Capture RE and
   click Properties.
10. Select "Use responses created from the turnaround dialog."
11. Start Windows Explorer and locate the recording file you created.
12. Right-click the file and click Properties.
13. Under Attribute, click to select the Read-only check box.
14. Install Sna\Comti\Tutorials\CedarBank\CICSLink\Cedar.tlb in a new
   Microsoft Transaction Server (MTS) package. Use the tutorial
   instructions as necessary to complete the process.
   new Diagnostic Capture RE.
   Result: The application displays a dialog box with the error message:
      (1300) COM Transaction Integrator was unable to allocate a state
      machine to process the method call (progress=2, hr=0x80040111).
18. Click Start on the Windows NT Taskbar. Point to Programs, point to
   Administrative Tools, and then click Event Viewer.
The following four error entries appear in the Event Log.
   Source:   COMTI
   Type:     Error
   Category: General
   (103) An error occurred during object creation and couldn't be reported
   to the client:
   Exception description:
   (1773) Capture could not update summary information in recording file
   c:\program files\sna\comti\recordings\BUG202.rcd. Make sure that the
   recording file is not marked as Read Only.
   Explanation:
   An Automation exception was formatted but couldn't be returned to the
   client because the error occurred during object creation. The exception
   shown above describes the error. An HRESULT of CLASS_E_CLASSNOTAVAILABLE
   was returned to the client application.
   Action:
   The error may be caused by communication problems or configuration
   errors on your system. See the exception description for corrective
   actions.
   Source:   COMTI
   Type:     Error
   Category: StMachDisp
   (300) COM Transaction Integrator's state machine dispenser was unable to
   create a new state machine object
   Progress Code: 6
   HRESULT: 0x80040111
   Explanation:
   COM Transaction Integrator was unable to create and initialize a new
   state machine object in response to a client request. The progress code
   and HRESULT above indicate the source and nature of the error.
   Action:
   Determine the meaning of the HRESULT shown above and proceed
   accordingly.
   Source:   COMTI
   Type:     Error
   Category: StMachDisp
   (301) COM Transaction Integrator's state machine dispenser was unable to
   allocate a state machine object
   Progress Code: 2
   HRESULT: 0x80040111
   Explanation:
   COM Transaction Integrator was unable to allocate a new or existing
   state machine object in response to a client request. The progress code
   and HRESULT above indicate the source and nature of the error.
   Action:
   Determine the meaning of the HRESULT shown above and proceed
   accordingly.
   Source:   COMTI
   Type:     Error
   Category: General
   (102) COM Transaction Integrator reported the following exception to a
   client:
   Component: Cedar.Bank.1
   Method: cedrbank
   Exception description:
   (1300) COM Transaction Integrator was unable to allocate a state machine
   to process the method call (progress=2, hr=0x80040111).
   Explanation:
   An Automation exception representing an error condition was returned to
   a COM Transaction Integrator client. The description shown above
   contains more information about the exception that was reported.
   Action:
   The exception may be caused by communication problems or errors in your
   host application. See the exception description for corrective actions.
   Event ID: 803
   Source:   COMTI CapturePlayback
   Type:     Error
   Category: Recording
   (803) COM Transaction Integrator recording object failed to update a
   recording file for a capture or playback Remote Environment:
   Recording File Identifier:
   {6F3BF771-BE88-11D1-B04D-00C04FD5BD02}
   Exception Description:
   (8336) Unable to open recording
   c:\program files\sna\comti\recordings\test.rcd for writing,
   HRESULT = 0x80030005.
   Explanation:
   The recording object failed in servicing a request to update the summary
   information in a recording file. This failure may indicate that the
   recording file path is invalid, that the user lacks permission to modify
   a file in the folder identified by the recording path, or that the
   recording file is read-only.
   Action:
   Start the COMTI Management Console. Select the Remote Environments
   folder. Locate the capture or playback Remote Environment associated
   with the recording file. Right-click to view action options, and select
   Properties. Select the Recording tab to view recording file information.
   Examine the recording file path and make sure that it is valid. If the
   Create Date field is blank, the recording object does not recognize the
   file as a valid recording, and it may be corrupted. If the Create Date
   field is valid, make sure that the recording is not identified as read-
   only. To create a new recording file, enter a unique path name and click
   Apply. To use a different existing recording file, use the Browse key to
   select a different recording file and click Open.
Keywords          : kbbug1.00 CTICapture CTIPlayback CTITurnaround 
Version           : WINDOWS:1.0
Platform          : WINDOWS
Issue type        : kbbug