INF: EZY1309E IBM Runtime Error on Mainframe Using CICS MS Link Programming Model and TCP/IP Transport With AuthenticationID: Q221533
|
A runtime error can occur on the mainframe when one is using COMTI with the CICS MS Link programming model and TCP/IP data transmission to the mainframe.
The error involves the IBM Listener program that runs in the CICS region. The following error message appears in the CICS CSMT message log:
EZY1309E mm/dd/yy hh:mm:ss GIVESOCKET FAILURE TRANS tttt TASKID= nnnn ERRNO= 46 INET ADDR= iii.iii.iii.iii PORT= pppp
The ERRNO=46 socket error has the following explanation:
EPFNOSUPPORT: The specified protocol family is not supported or the specified domain for the client identifier is not AF_INET=2.
A customer solved this problem by applying the IBM PTF (Program Temporary Fix) number UQ20701 to their TCP/IP system on the mainframe. This PTF fixes a problem in the IBM Listener program, EZACIC02.
Information about the error message can be found in the following two IBM manuals:
Additional query words:
Keywords :
Version : WINDOWS:4.0 SP2
Platform : WINDOWS
Issue type : kbinfo
Last Reviewed: March 30, 1999