ID: Q115292
The information in this article applies to:
If invisible buttons are sized too small in a FoxPro for Windows screen, the invisible buttons cannot be found when the screen is transported and opened for modification in FoxPro for MS-DOS. When you click anywhere on the transported screens in FoxPro for MS-DOS, the system will hang.
To prevent this problem, do one of the following:
-or-
Microsoft has confirmed this to be a problem in the Microsoft products listed at the beginning of this article. We are researching this problem and will post new information here in the Microsoft Knowledge Base as it becomes available.
1. Create a screen in FoxPro for Windows with two or more invisible
buttons.
2. Add one set of invisible buttons that consists of two or more invisible
buttons.
3. Resize the invisible button until the invisible button is one row in
height. For example, a set of invisible buttons that consists of three
invisible buttons should look like this--///--when resized to only one
row in height.
4. Save the screen without the environment and close the screen.
5. Open the screen in FoxPro for MS-DOS to invoke the transporter.
6. Choose the Transport & Open button in the Transport dialog box. When the
transporter is done, note that the invisible button cannot be found.
7. Click anywhere on the transported screen. FoxPro for MS-DOS will hang.
NOTE: When a screen (.SPR) is run in FoxPro for MS-DOS, an invisible button must be a minimum of 1 row by 1 column in the SIZE clause in order to be found with a mouse or for it to show as selected when it is tabbed to.
Additional reference words: FoxDos 2.50 2.50a 2.50b 2.60 buglist2.50 buglist2.50a buglist2.50b buglist2.60 buglist2.60a stop responding lock up halt freeze KBCategory: kbprg kbbuglist KBSubcategory:
Last Reviewed: April 18, 1995