ID: Q123207
2.50 2.50a 2.50b 2.60 2.60a WINDOWS kbtool kbbuglist
The information in this article applies to:
- Microsoft FoxPro for Windows versions 2.5, 2.5a, 2.5b, 2.6, 2.6a
Generating a screen when its corresponding .SPR file is open causes the following error if additional .SCX files are also open:
Menu Manager Internal Consistency Error
Close the .SPR file before generating the screen. If there is a chance that the .SPR file may be left open, close any other open .SCX files.
Microsoft has confirmed this to be a problem in FoxPro versions 2.5, 2.5a, 2.5b, 2.6, and 2.6a for Windows. We are researching this problem and will post new information here in the Microsoft Knowledge Base as it becomes available.
1. Connect to the CUSTOMER.DBF database by using the USE command.
2. Create a quick screen. Then save it as TEST.SCX, and generate it.
3. Open the TEST.SPR file.
4. Open another <screenname>.SCX file.
5. Generate TEST.SCX.
6. Press a key to continue after the "File in use" error. Now you'll see
error, "Menu Manager Internal Consistency Error," which is usually
followed by a general protection (GP) fault.
NOTE: The correct behavior is the redisplay of the Generate Screen
dialog.
Additional reference words: FoxWin 2.50 2.50a 2.50b 2.60 2.60a buglist2.50
buglist2.50a buglist2.50b buglist2.60 buglist2.60a gpf
KBCategory: kbtool kbbuglist
KBSubcategory: FxtoolSbuilder
Keywords : FxtoolSbuilder kbbuglist
Version : 2.50 2.50a 2.50b 2.60 2.60a
Platform : WINDOWS
Last Reviewed: May 2, 1996