BUG: Project Manager Adds the Same VCX Twice During BuildLast reviewed: January 24, 1997Article ID: Q141524 |
The information in this article applies to:
SYMPTOMSWhile you're working with a project that contains a Visual Class Library and one of the Build Options (Project, Application, or Executable) has been selected, if the Project Manager encounters a reference to a Visual Class Library that does not exist in the Project, it will offer the user an opportunity to locate it. If, during this process, the user locates and selects the Visual Class Library that already exists in the project, the Project Manager will permit it to be added a second time.
WORKAROUNDIf this occurs, one of the two references to the Visual Class Library should be eliminated by using the Remove option. Care should be taken to remove the file -- don't delete it from the disk.
STATUSMicrosoft has confirmed this to be a problem in the Microsoft products listed at the beginning of this article. We are researching this problem and will post new information here in the Microsoft Knowledge Base as it becomes available.
MORE INFORMATION
Steps to Reproduce Problem
|
KBCategory: kbtool kbbuglist