ID: Q114657
2.60 | 2.60
WINDOWS | MS-DOS
kbtool kbprg kbbuglist
The information in this article applies to:
When you choose the Run or Print button in the Catalog Manager, the following error message will appear:
Error 10 (Syntax error.) occurred in WZSHOW. Catalog Manager will
restart.
This behavior is caused by a problem in the source code of CATALOG.APP.
To avoid this problem, do not choose the Run or Print button when no valid options are selected. Instead, select a valid option (report, label, screen, and so on) before choosing the Run or Print button.
Microsoft has confirmed this to be a problem in FoxPro version 2.6 for Windows and FoxPro version 2.6 for MS-DOS. We are researching this problem and will post new information here in the Microsoft Knowledge Base as it becomes available.
1. Start the Catalog Manager and open the sample catalog.
2. USE the customer table, so that the Screen, Report, and Label tabs each
have a separator bar.
3. Go to the Screen, Report, or Label tab, click the separator bar, and
choose Run or Print. It may not be possible to reproduce the problem if
the separator bar is at the top of the list box. Click the separator bar
when it is not at the top of the list box. For example:
|============|
|Text Here |
|------------| <<- click on the separator bar
|Text Here |
|============|
The following error message will appear:
Error 10 (Syntax error.) occurred in WZSHOW. Catalog Manager will
restart.
In the FoxPro for MS-DOS, the problem will occur when the separator bar is
in the first slot in the scrolling list.
Additional reference words: FoxDos FoxWin 2.60 buglist2.60 sample KBCategory: kbtool kbprg kbbuglist KBSubcategory: FxtoolCatman
Keywords : FxtoolCatman kbbuglist
Version : 2.60 | 2.60
Platform : MS-DOS WINDOWS
Last Reviewed: May 2, 1996