ACC2: Errors After Reinstalling MS Access to WorkstationID: Q120058
|
Advanced: Requires expert coding, interoperability, and multiuser skills.
When you reinstall Microsoft Access to a workstation and then start
Microsoft Access, you receive an error message similar to:
Couldn't find file 'G:\ACCESS\SYSTEM.MDA'
Tried to load module with duplicate procedure definition: doc_CleanObjTables
When you reinstall Microsoft Access to the workstation, incorrect settings
are written to the MSACC20.INI file. For example, the line
SystemDB=G:\ACCESS\WORKDIR\SYSTEM.MDA
SystemDB=G:\ACCESS\SYSTEM.MDA
[Libraries]
G:\ACCESS\WORKDIR\wzLib.mda=rw
G:\ACCESS\WORKDIR\wzTable.mda=rw
G:\ACCESS\WORKDIR\wzQuery.mda=rw
G:\ACCESS\WORKDIR\wzFrmRpt.mda=rw
G:\ACCESS\WORKDIR\wzBldr.mda=rw
[Libraries]
G:\ACCESS\WORKDIR\wzLib.mda=rw
G:\ACCESS\WORKDIR\wzTable.mda=rw
G:\ACCESS\WORKDIR\wzQuery.mda=rw
G:\ACCESS\WORKDIR\wzFrmRpt.mda=rw
G:\ACCESS\WORKDIR\wzBldr.mda=rw
wzLib.mda=rw
wzTable.mda=rw
wzQuery.mda=rw
wzFrmFpt.mda=rw
wzBldr.mda=rw
Make the following changes to the MSACC20.INI file:
Microsoft has confirmed this to be a problem in Microsoft Access version 2.0. We are researching this problem and will post new information here in the Microsoft Knowledge Base as it becomes available.
For more information about settings in the MSACC20.INI file, search for "MSACC20.INI," and then "Customizing MSACC20.INI Settings" using the Microsoft Access Help menu.
Additional query words: net network
Keywords : kberrmsg kbsetup StpNet
Version : 2.0
Platform : WINDOWS
Issue type : kbbug
Last Reviewed: April 7, 1999