Err Msg: Cannot Start Communications with the Desktop Computer

ID: Q177865

The information in this article applies to:

SYMPTOMS

When you establish an infrared connection between a Handheld PC (H/PC) and a desktop computer, you may receive the following error message:

   Cannot start communications with the desktop computer. No carrier was
   detected on the communications port. Please verify that the
   communications line is connected and active.

CAUSE

This error message can occur if any of the following conditions exists:

RESOLUTION

To resolve this behavior, use the following steps, checking to see if the issue is resolved after each step:

1. Position your infrared ports out of direct sunlight.

2. Move your infrared ports within the connection range. Infrared devices

   should be no more than 3 to 6 feet apart and no less than 6 to 9 inches
   apart. The angle of the cone of infrared transmission is 30 degrees.

3. Install new batteries in your infrared device or plug in an AC adapter.

Additional query words: synch synchronization ir linking 2.00

Keywords          : kberrmsg kbtool wince handheld 
Version           : WINDOWS:2.0
Platform          : WINDOWS

Last Reviewed: April 29, 1998