DOCUMENT:Q137045 16-NOV-1999 [pcmail] TITLE :X400: Using a 3Com Etherlink II Network Card for TP4/CLNS PRODUCT :Microsoft Mail For PC Networks PROD/VER:MS-DOS:3.2 OPER/SYS: KEYWORDS: ====================================================================== ------------------------------------------------------------------------------- The information in this article applies to: - Microsoft Mail Gateway to X.400, version 3.2 ------------------------------------------------------------------------------- SYMPTOMS ======== When you try to configure the Mail Gateway to X.400 using TP4/CLNS over a 3Com Etherlink II (assy 2227-04 rev.F) or 3Com Etherlink II TP (assy 8782- 01 rev.d1), the gateway may hang while initializing. WORKAROUND ========== Try to run the GETMAC.EXE utility (C:\TP4\UTIL\), included with the X.400 Gateway. If this utility also hangs, then remove the 3Com card and substitute a different card. NOTE: At this time, the above cards are the only ones known to have this conflict. Additional query words: 3.20 ====================================================================== Keywords : Technology : kbMailSearch kbMailGateSearch kbZNotKeyword3 kbMailGatex400320 Version : MS-DOS:3.2 ============================================================================= THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY. Copyright Microsoft Corporation 1999.