IntelliPoint Setup Does Not Modify Autoexec.bat on Floppy Disk

ID: Q137999

1.10 WINDOWS kbhw kbenv

The information in this article applies to:

SYMPTOMS

When you set up the IntelliPoint or IntelliType software on a computer that starts from a floppy disk, the Autoexec.bat file on the hard disk is modified by Setup, rather than the Autoexec.bat file on the floppy disk.

CAUSE

Setup assumes that drive C is the boot disk, and modifies the startup files on that drive.

RESOLUTION

Transfer the changes made by Setup to the floppy disk. To do so, copy the modified lines from the Autoexec.bat file on the hard disk to the Autoexec.bat file on the floppy disk.

For example, copy the following lines to the Autoexec.bat file on the floppy disk:

   c:\msinput\itype.exe
   set msinput=c:\msinput

STATUS

Microsoft is researching this problem and will post new information here in the Microsoft Knowledge Base as it becomes available.

KBCategory: kbhw kbenv KBSubcategory: mnk Additional reference words: 1.10

Keywords          : mnk 
Version           : 1.10
Platform          : WINDOWS

Last Reviewed: September 13, 1996