Magnavox 80286, Serial Mouse Doesn't Work in Windows or MS-DOS

ID: Q81885


The information in this article applies to:


SUMMARY

Magnavox 80286 systems have a bus mouse port, which may prevent the MS-DOS mouse driver from installing, or the driver may install but the mouse may not function. In addition, the mouse may not work in Windows.

The MS-DOS driver should install when the /C1 or /C2 switch is applied to the driver for a Microsoft serial Mouse. Microsoft Mouse driver version 8.0 or later may be required for the Microsoft Mouse to work in Windows.


MORE INFORMATION

It is best to first install the Mouse to work under MS-DOS. To install a serial Mouse (including the BallPoint Mouse) under MS-DOS, do the following:

  1. Exit from Windows (if Windows is running).


  2. At the mouse subdirectory (for example, C:\MOUSE), type the following command:
    
          mouse off 
    If the message
    EXISTING MOUSE DRIVER DISABLED
    is displayed, boot the machine and go to step 3.

    If the message
    UNABLE TO DISABLE MOUSE DRIVER, CONTROL PANEL IS ACTIVE
    is displayed, enter the command
    
          cpanel off 
    and repeat step 2.


  3. At the command prompt, type
    
          mouse/c1 
    -or-
    
          mouse /c2 
    to install the mouse. If the mouse does not install, there may be a hardware conflict or other limitation. Do a clean MS-DOS boot.


  4. If the mouse driver installed in step 3, run CPANEL.COM. If a mouse cursor appears in Control Panel, then a solution exists.


  5. For MS-DOS, add the appropriate switch (/C1 or /C2) to the AUTOEXEC.BAT or CONFIG.SYS file.


To use the mouse in Windows, you will need to modify the MOUSE.INI file in the mouse subdirectory. To modify the MOUSE.INI file to work with a mouse in Windows, do the following:

   The MouseType= line should be modified to read MouseType=Serial1 or
   MouseType=Serial2, depending on whether /C1 or /C2 worked,
   respectively.

   Note: The MOUSE.INI file only exists for Microsoft Mouse driver
   versions 8.0 and later. 
It is not necessary to reboot before entering Windows.

The product included here, Magnavox 80286, is manufactured by vendors independent of Microsoft; we make no warranty, implied or otherwise, regarding this product's performance or reliability.

Additional query words: 3.0 3.00 3.00a 8.00 8.10 3rdparty 8.20 9.00 8.0 3.0 3.00 3.00a


Keywords          : win31 win30 
Version           : 8.x 9.00
Platform          : MS-DOS 
Issue type        : 

Last Reviewed: August 8, 1999