ID: Q172510
The information in this article applies to:
When you try to restart the Content Replication System (CRS) service, you may see the following error message:
CRS returned the following CRS specific error message: 3221240592
NOTE: You may see the error message in the mail notification that CRS
sends. The error message can also occur in the event viewer.
You must convert the error code in order to get a meaningful error message. Do the following procedure:
1. Convert the error number to hex, = C0003B10 2. Take the last four digits of the converted number, = 3B10 3. Convert this four-digit hex number back to decimal, = 15120 4. Check this error number on CRS documentation.
For this particular error, 15120 means:
Product Expired Error
Source: CRS
ID: 15120
Text: Thank you for your interest in Content Replication System.
This software expires March 31, 1997 and will no longer function after
that date. Please acquire the final retail version of this software.
Severity: Error
Name: CRS_ERROR_PRODUCT_EXPIRED
Meaning: You are using evaluation software and it has expired.
Cause: Your evaluation time is up.
Recommendation: Purchase the retail version of CRS.
Version : 1.00,2.00
Platform : WINDOWS
Issue type : kbprb
Last Reviewed: February 17, 1998