PRB: Error Code = 0x00E0052A Installing Primary Site Controller

Last reviewed: September 16, 1997
Article ID: Q173229
The information in this article applies to:
  • Microsoft Message Queue Server version 1.0

SYMPTOMS

Setup for a Primary Site Controller (PSC) may fail with the following error message:

   Unable to create the site on the information server.

   Create site operation failed, because there is
   already a PSC with the same name. PSC name
   must be unique.
   Error code = 0x00E0052A.

CAUSE

This error occurs when site information already exists in the Message Queue Information Store (MQIS) that refers to the computer name as the Site Controller. That is, a Site viewable in MQExplorer identifies the current computer as its site controller.

WORKAROUND

To work around this problem, delete the site for which the computer appears as the PSC. Then restart setup.

MORE INFORMATION

This behavior is by design.

REFERENCES

For more information, visit the Web site at:

Keywords          : kbsetup MQDeploy MQInstall
Version           : WINDOWS NT:1.0
Platform          : winnt
Issue type        : kbprb
Solution Type     : kbworkaround


================================================================================


THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.

Last reviewed: September 16, 1997