OFF97: Problems After Reawakening Suspended Computer

ID: Q162153


The information in this article applies to:


SYMPTOMS

When you return your computer to its original running state after you use the Advanced Power Management Suspend feature, you may receive the following error message:

This program has performed an illegal operation and will be shut down. If the problem persists, contact the program vendor.
If you click Details, you receive an error message similar to one of the following:
OSA caused an exception c0000006H in module MSO97.DLL at 0137:3084e02a.
EXCEL caused an invalid page fault in module KERNEL32.DLL at 0137:bff857e7.
WINWORD caused an exception c0000006H in module WINWORD.EXE at 0137:301c69f0.
WINWORD caused an exception c0000006H in module WINWORD.EXE at 0137:3028ba66.
WINWORD caused an exception c0000006H in module MSO97.DLL at 0137:306d35a8.
WINWORD caused an invalid page fault in module KERNEL32.DLL at 0137:bff857e7.
POWERPNT caused an invalid page fault in module POWERPNT.EXE at 0137:30291126.
MSACCESS caused an invalid page fault in module MSACCESS.EXE at 0137:30270000.
BINDER caused an exception c0000006H in module MSO97.DLL at 0137:3084e019.
BINDER caused an exception c0000006H in module MSO97.DLL at 0137:30843c72.


CAUSE

These problems occur if all of the following conditions are true:


WORKAROUND

To work around this problem, do either of the following:

NOTE: This problem should not occur if you perform a Typical or Custom installation of Microsoft Office 97. Only Run From Server installations are affected.


STATUS

Microsoft has confirmed this to be a problem in the Microsoft products listed at the beginning of this article. We are researching this problem and will post new information here in the Microsoft Knowledge Base as it becomes available.


MORE INFORMATION

If your computer supports it, you can use the APM (Advanced Power Management) feature in Microsoft Windows 95 to control how your computer uses and conserves power. One of the features included with APM is the Suspend feature; on the Start menu, when you click Suspend, the contents of your computer's memory are written to your hard disk, and the computer is essentially shut down. When you return your computer to its original running state, the programs that you were running when you activated the Suspend feature are still available.

When you use the Suspend feature, all network connections between your computer and other computers are shut down. When you return your computer to its original running, some of the network connections may not be properly re-established by Windows 95. Therefore, any Microsoft Office 97 program you run from a network connection generates one or more of the error messages listed when you cancel the suspended state on the computer. The programs are loaded into memory correctly, but the network connection may be broken.

Additional query words: 97 OFF97 XL97 WORD97 ACC97 PPT97 restore resume awaken reawaken reawakened


Keywords          : kberrmsg offrfs 
Version           : WINDOWS:97
Platform          : WINDOWS 
Issue type        : 

Last Reviewed: July 27, 1999