The information in this article applies to:
When you use the Component Builder (CB) to create a component library (.tlb) file manually (this is, without using the Import COBOL Wizard), you can define a method with parameters in an order that prevents COBOL generated by the CB COBOL Export facility from compiling properly.
If there are two or more parameters that are arrays whose actual counts depend on the value of other parameters, those actual count parameters must appear before the first array.
You generate a component library with the following four parameters:
Count1 (integer)
Array1 (anything)
Count2 (integer)
Array2 (anything)
The generated COBOL would be similar to this:
01 DFHCOMMAREA.
05 COUNT1 PIC S9(4) COMP. INOUT
05 ARRAY1 OCCURS 10 TIMES INOUT
DEPENDING ON COUNT1 OF DFHCOMMAREA
PIC S9(9) COMP.
05 COUNT2 PIC S9(4) COMP. INOUT
05 ARRAY2 OCCURS 10 TIMES INOUT
DEPENDING ON COUNT2 OF DFHCOMMAREA
PIC S9(9) COMP.
This COBOL produces the following error message when compiled on MVS:
115 IGYGR1137-S "OCCURS DEPENDING ON" object "COUNT2" was defined in
a variably located area. Execution results will be unpredictable.
The solution to this problem is to use CB to arrange the parameters in the following order
COUNT1
COUNT2
ARRAY1
ARRAY2
and then regenerate the COBOL using the COBOL Export facility.