DOCUMENT:Q148312 13-JUN-2001 [sna] TITLE :No RTM Data Generated If 3270 Session Uses Exception Response PRODUCT :Microsoft SNA Server PROD/VER:WINDOWS:2.11,2.11 SP1 OPER/SYS: KEYWORDS:kbnetwork ====================================================================== ------------------------------------------------------------------------------- The information in this article applies to: - Microsoft SNA Server, versions 2.11, 2.11 SP1, on platform(s): - the operating system: Microsoft Windows NT ------------------------------------------------------------------------------- SYMPTOMS ======== The SNA Server 2.11 3270 Windows and Windows NT applets support the generation of response time monitor (RTM) performance data, which SNA Server then provides to NetView. However, if host subsystem (such as CICS, IMS, TSO) is configured to use exception response protocol instead of definite response protocol, the 3270 applet does not report performance data to the SNA Server. This causes the SNA Server to fail reporting data to NetView. NOTE: For response time monitor (RTM) data to be reported by SNA Server to NetView, a 3270 emulator must supply performance data on STATUS-Acknowledge messages to SNA Server as described in the SNA Server Emulator Interface Specification (EIS), section 3.3.15 and 4.8. SNA Server has supported the response time monitor interface since version 2.0. The 3270 applet did not support the interface until version 2.11. This problem also occurs on Attachmate Extra! version 4.2. Earlier versions of Extra! do not support the SNA Server response time monitor reporting feature. Contact Attachmate Technical Support for availability of an Extra! update. CAUSE ===== If you use the exception response protocol on the 3270 applet session, Status-Ack messages are not sent to SNA Server. No response time monitor data has been reported to the server, even if the response time monitor feature has been enabled. RESOLUTION ========== To work around this problem, change the host subsystem configuration so that the 3270 applet sessions use definite response. To correct this problem, apply the fix mentioned below. STATUS ====== Microsoft has confirmed this to be a problem in SNA Server 2.11 and 2.11 Service pack 1. This problem was corrected in the latest Microsoft SNA Server 2.11 U.S. Service Pack. For information on obtaining the service pack, query on the following word in the Microsoft Knowledge Base (without the spaces): S E R V P A C K Additional query words: prodsna ====================================================================== Keywords : kbnetwork Technology : kbAudDeveloper kbSNAServSearch Version : WINDOWS:2.11,2.11 SP1 Issue type : kbbug Solution Type : kbfix ============================================================================= THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY. Copyright Microsoft Corporation 2001.