PRB: Can't Set Working Directory by Using .ini File

Last reviewed: February 25, 1997
Article ID: Q153506
The information in this article applies to:
  • Microsoft Visual SourceSafe for Macintosh, version 4.0a, 5.0

SYMPTOMS

Defining a working directory from either the Srcsafe.ini or Ss.ini file does not work. Any files that are checked out are stored to a different location from that specified.

CAUSE

The working directory is defined by default by whatever directory is defined in MPW's Directory menu.

RESOLUTION

Type the following statement in the appropriate .ini file (after a project section) to cause Visual SourceSafe to use the working directory specified:

      Force_Dir=Yes

STATUS

This behavior is by design.


KBCategory: kbsetup kbprb
KBSubcategory: vss
Additional reference words: 5.00 4.00a




THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.