BUG: If RPC Is Used, SQL Server ODBC Driver Converts in Place

ID: Q171910


The information in this article applies to:

BUG #: 17119 (SQL 6.5)


SYMPTOMS

In a self-written ODBC program that executes a prepared statement at a SQL Server (set up with an OEM code page, such as code page 437 or 850) the data in the buffer passed in the rgbValue parameter of SQLBindParameter is converted from ANSI to OEM after issuing the SQLExecute. This can be observed when using extended characters in the character buffer.

In Microsoft Access, when you retrieve records in an attached ODBC table, each field in a record contains the "#Deleted" error message. This happens if the attached SQL Server table contains extended characters in the primary key of that record.

This problem occurs if all of the following conditions are true:


CAUSE

The ODBC SQL Server driver invokes the stored procedure upon SQLExecute by remote procedure call (RPC). In this scenario, a passed parameter is converted in place. Because Microsoft Access reuses these parameters to match the returned data to the values of the primary key, it shows "#Deleted" in the affected records.


WORKAROUND

To work around this problem, do one of the following, as appropriate for your application:


STATUS

Microsoft has confirmed this to be a problem in the products listed at the beginning of this article. We are researching this problem and will post new information here in the Microsoft Knowledge Base as it becomes available.


MORE INFORMATION

This problem also occurs if you use the MS Code page Translator instead of the "Convert OEM to ANSI characters" check box.



Additional query words: Ansi2Oem Oem2Ansi AnsiToOem OemToAnsi CharToOem OemToChar cp codepage


Keywords          : kbinterop kbprg kbusage SSrvProg kbbug6.50 kbbug6.00 
Version           : 2.65.0201