ID: Q122855
A client bulk copy program (BCP) application may hang on a call to bcp_sendrow.
The DB-Library bcp_sendrow function does not time-out after the period of time specified by dbsettime has expired. If the client application does not receive a response from the server, it will wait indefinitely.
This situation is usually related to an underlying network connectivity problem. Address any reliability issues with the network in order to minimize the likelihood of the problem reoccurring.
Additional query words: Windows NT dblib
Keywords : kbnetwork kbprg SSrvBCP SSrvDB_Lib SSrvProg SSrvVisB
Version : 4.2 | 4.2 4.21 | 4.2
Platform : MS-DOS OS/2 WINDOWS
Last Reviewed: May 1, 1997