Appctl16.exe Doesn’t Look in Package Source Directory for Config

ID: Q153645

The information in this article applies to:

SYMPTOMS

When you configure the Drive mode for "Requires Specific Drive Letter" under the program item properties for a shared application and place the script processor and configuration script for your shared application in the package source directory, Appctl16.exe only looks in the Mstest directory for the configuration script.

The following error occurs when you attempt to launch the shared application:

   Cannot find application configuration script

This problem does not occur when you use "Runs with UNC Name" as the Drive mode. Appctl16.exe works using either Drive mode.

STATUS

Microsoft has confirmed this to be a problem in Microsoft Systems Management Server versions 1.0 and 1.1. This problem was corrected in Microsoft Systems Management Server version 1.2.

Additional query words: prodsms pgc

Keywords          : kbnetwork kbbug1.00 kbbug1.10 kbfix1.20 smspgc 
Version           : 1.0 1.1 1.2
Platform          : WINDOWS

Last Reviewed: April 25, 1997