ID: Q156393
The information in this article applies to:
You will receive the following error message when an apartment threaded component uses a single threaded object:
0x8001010E
RPC_E_WRONG_THREAD
To work around this problem, do not use single threaded objects from an apartment threaded component.
Microsoft has confirmed this to be a problem in Microsoft Transaction Server version 1.0. This problem was corrected in Microsoft Transaction Server version 1.1. For information on obtaining version 1.1, please see the following article the Microsoft Knowledge Base:
ARTICLE-ID: Q168031
TITLE : How to Obtain Microsoft Transaction Server Version 1.1
Additional query words: Obj
Keywords : kbprg kbusage kbbug1.00 kbfix1.10 TSrvGen
Version : 1.0
Platform : WINDOWS
Issue type : kbbug
Solution Type : kbfix