ACC: Error Message When Importing Informix Delimited Text File

ID: Q99406


The information in this article applies to:


SYMPTOMS

Moderate: Requires basic macro, coding, and interoperability skills.

When you attempt to import an Informix delimited text file that uses the pipe (|) symbol as a delimiter, you receive the following error message:

Name " contains invalid characters


CAUSE

When you export in Informix as text delimited and you specify the pipe symbol as the delimiter, Informix adds an extra pipe symbol at the end of the line. When you import this file to Microsoft Access by specifying "First row contains field names," Microsoft Access assumes there is another field after the last pipe symbol. Since the value is null, Microsoft Access returns the above error message.


RESOLUTION


MORE INFORMATION

Steps to Reproduce Behavior


  1. Create a text file in Microsoft Windows Notepad as follows:
    
          A|B|C|
          1|2|3| 

    Place a pipe symbol between each character. The pipe symbol is usually found on the backslash (\) key on your keyboard.


  2. Save the file as INFORMIX.TXT.


  3. Open a database in Microsoft Access.


  4. From the File menu, choose Import.


  5. Select Text (delimited) as your data source and choose Import.


  6. Select the INFORMIX.TXT file that you created in step 1. Choose OK.


  7. The Import Options dialog box appears. Select the First Row Contains Field Names check box, then choose the Options button.


  8. In the Field Separator combo box, type the pipe symbol and choose OK. The above error message appears.


Informix is manufactured by Informix Software, Inc., a vendor independent of Microsoft; we make no warranty, implied or otherwise, regarding this product's performance or reliability.


Keywords          : kb3rdparty IsmTxtd 
Version           : 1.0 1.1 2.0
Platform          : WINDOWS 
Issue type        : kbprb 

Last Reviewed: March 23, 1999