XL97: Error When Passing an Array Value Between Macros

ID: Q158746


The information in this article applies to:


SYMPTOMS

When you run a Visual Basic for Applications macro in Microsoft Excel 97, you may receive the following error message:

Run-time error '10':
This array is fixed or temporarily locked.


CAUSE

This behavior will occur if the following conditions are all true:

This behavior is by design of Microsoft Excel 97.

NOTE: This behavior is a change from earlier versions of Microsoft Excel.


WORKAROUND

Microsoft provides programming examples for illustration only, without warranty either expressed or implied, including, but not limited to, the implied warranties of merchantability and/or fitness for a particular purpose. This article assumes that you are familiar with the programming language being demonstrated and the tools used to create and debug procedures. Microsoft support professionals can help explain the functionality of a particular procedure, but they will not modify these examples to provide added functionality or construct procedures to meet your specific needs. If you have limited programming experience, you may want to contact the Microsoft fee-based consulting line at (800) 936-5200. For more information about the support options available from Microsoft, please see the following page on the World Wide Web:

http://www.microsoft.com/support/supportnet/refguide/
The following workarounds assume that you created a Visual Basic module with the following code:

   Dim MyArray() As Integer

   Sub Macro1()     'The first macro
       ReDim MyArray(10)
       Macro2 MyArray(1)
   End Sub

   Sub Macro2(X)    'The second macro
       ReDim MyArray(20)
   End Sub 
The array MyArray is initialized at the module level; so, it is available to all macros within the module. The first macro redimensions the array, and then passes an element of the array to the second macro. The second macro refers to the element in the array by reference, not by value.

NOTE: If you run Macro1, you receive the error message.

To prevent the problem from occurring, use either of the following methods.

Method 1

In the second macro, use the keyword ByVal to force the macro to refer to the element in the array by value, not by reference. For example, change the second macro to the following:

   Sub Macro2(ByVal X)    'Note the "ByVal" keyword.
       ReDim MyArray(20)
   End Sub 

Method 2

Use an intermediate variable to pass the value from one macro to the other. For example, change the first macro to the following:

   Sub Macro1()
       ReDim MyArray(10)
       Z = MyArray(1)     'Set the intermediate variable value.
       Macro2 Z           'Run the second macro and pass the value.
   End Sub 
By using an intermediate variable to send the value to the second macro, you prevent the second macro from referring to locations within the array's memory. You can then redimension the array without receiving an error message.


MORE INFORMATION

When you pass a variable from one macro to another macro in Microsoft Excel, the actual value of the variable is not passed between macros. Instead, a reference to the value's location in memory is passed; this is called passing a value by reference. You can also pass a value by value by using the keyword ByVal.

If you pass an element of an array from one macro to another by reference, and then attempt to redimension the array by using the ReDim method, you receive the error message in this article. This behavior occurs because the array's size is locked when a macro refers to it. Only when the reference is released can the array be redimensioned.

Note that this limitation does not apply to earlier versions of Microsoft Excel.

Additional query words: XL97


Keywords          : kberrmsg kbprg kbdta kbdtacode KbVBA xlvbmigrate 
Version           : WINDOWS:97
Platform          : WINDOWS 
Issue type        : kbprb 