How To Get 32-bit Scroll Position During Scroll MessagesID: Q152252
|
The current scroll bar position accompanying the SB_THUMBTRACK and SB_THUMBPOSITION type of scroll messages is only 16-bits wide. Functions such as GetScrollPos, SetScrollPos, GetScrollRange, and SetScrollRange can handle 32-bit value scroll-box positions. This article discusses how the GetScrollInfo call can be used to retrieve 32-bit scroll position during scroll messages.
One of the arguments to the MFC scroll message handlers, OnHScroll and
OnVScroll, is the scroll box position. This argument is meaningful only in
the case of scroll messages with scroll bar code SB_THUMBPOSITION and
SB_THUMBTRACK. This value, even though of type UINT, is really of type
short int. In other words, the scroll thumb position is only 16-bits wide.
This behavior occurs because Windows sends the thumb position in the High
Word of WPARAM accompanying the scroll message.
To obtain 32-bit scroll positions, the OnxScroll handler should make a call
to GetScrollInfo with the mask set to SIF_TRACKPOS. The immediate position
of the scroll thumb is returned in the nTrackPos member of the SCROLLINFO
structure passed in to GetScrollInfo.
This functionality was embedded in MFC 4.0 classes and was handled by the
function CWnd::OnWndMsg. However, this gave rise to other problems. As a
consequence, the functionality was withdrawn in MFC 4.1 and it was left to
the user to extract 32-bit values for the scroll box. For more information
on this subject, please see the following article in the Microsoft
Knowledge Base:
Q147684 BUG: Sending WM_xSCROLL Messages Causes Invalid ASSERTThis method of extracting 32-bit scroll box positions works only in those scroll messages that are sent to a window when the user grabs the thumb and drags it. It is not possible to obtain 32-bit scroll box position in cases of programmatically sent SB_THUMBTRACK and SB_THUMBPOSITION scroll messages. First, the 32-bit information cannot be packed into the WPARAM of the messages because only the High Word contains the scroll position. Second, the nTrackPos member of the SCROLLINFO structure maintained for scroll bars cannot be set programmatically. Any calls to SetScrollInfo to set the immediate scroll positions are ignored by the operating system.
void CMyWnd::OnHScroll(UINT nSBCode, UINT nPos, CScrollBar* pScrollBar)
{
if(nSBCode == SB_THUMBTRACK || nSBCode == SB_THUMBPOSITION)
{
// First determine if the user scrolled a scroll bar control
// on the window or scrolled the window itself
HWND hWndScroll;
if ( pScrollBar == NULL )
hWndScroll = m_hWnd;
else
hWndScroll = pScrollBar->m_hWnd;
SCROLLINFO info;
info.cbSize = sizeof(SCROLLINFO);
info.fMask = SIF_TRACKPOS;
::GetScrollInfo(hWndScroll, SB_HORZ, &info);
nPos = info.nTrackPos;
}
//......
//......
}
Additional query words: 2.00 2.10 2.20 4.00 4.10 3.00 3.10 3.20 4.00 4.10 kbinf
Keywords : kbMFC KbUIDesign kbVC
Version : 2.00 2.10 2.20 4.00 4.10
Platform : NT WINDOWS
Issue type :