SUMMARY

This article contains important information not included in the Microsoft RPC programming documentation or in Help about Microsoft RPC version 2.0. This information is identical to the information provided in the RPCREAD.ME file in the Win32 SDK (MSTOOLS\SAMPLES\RPC\) for Windows NT version 3.5.

Microsoft RPC is a toolkit for developing distributed applications in C/C++. The toolkit includes:

MORE INFORMATION

This article is organized into the following sections:

Installation

The Windows NT SDK provides the components of the RPC toolkit as part of its standard installation. No additional installation is required. To produce MS-DOS and Windows 3.x RPC clients, install version 1.50 of the Microsoft Visual C/C++ development environment, and then install the MS- DOS/Win16 RPC tookit from disk. To install the MS-DOS/Windows 3.x version of the RPC toolkit, use the Setup program in the MSTOOLS\RPC_DOS\DISK1 directory.

Because the 16-bit MIDL compiler is no longer supported, you must develop applications using the 32-bit MIDL compiler. However, to write MS-DOS or Windows 3.x applications without a 32-bit C/C++ compiler capable of targeting MS-DOS, you must compile the IDL file with a 32-bit MIDL compiler on Windows NT. Then, compile the application and stubs using your C/C++ compiler. To write MS-DOS or Windows 3.x applications using a 32-bit C/C++ compiler that is capable of targeting MS-DOS, compile both the IDL file and C/C++ files on Windows NT.

Documentation

The RPC Programmer's Guide and Reference is available in Help and includes conceptual material, MIDL language and command-line references, and run-time API references.

Because many new features have been included in this version of Microsoft RPC, see the New in this Version of RPC help topic.

RPC sample program source files are available in the directory MSTOOLS\SAMPLES\RPC. The MSTOOLS\SAMPLES\RPC\README.TXT file describes each sample.

Before Using RPC

Read the following section on MIDL and run-time API issues before attempting to use this version of RPC. These sections contain important information that is not documented in Help.

MIDL Issues

The 16-bit MIDL compiler for MS-DOS or Windows 3.x is no longer supported. Use the 32-bit MIDL compiler switch /env with either the DOS or WIN16 option.

Note the following when using this version of the MIDL compiler:

Run-Time API Issues

When using the ncacn_spx and ncadg_ipx transports, the server name is exactly the same as the Windows NT server name. However, because the names are distributed using Novell protocols, they must conform to the Novell naming conventions. If a server name is not a valid Novell name, servers will not be able to create endpoints with the ncacn_spx or ncadg_ipx transports. The following is a partial list of characters prohibited in Novell server names:

   "  *  +  .  /  :  ;  <  =  >  ?  [  ]  \  |

When using ncadg_ipx on Windows 3.x or MS-DOS platforms, use the Windows NT 3.1 model of server naming. That is, a tilde, followed by the servers eight- digit network number, followed by its twelve-digit Ethernet address.

The ncacn_spx transport is not supported by the version of NWLink supplied with MS Client 3.0; however, ncadg_ipx is supported.

Backslashes are now optional in the host name for ncacn_np, for consistency with the other transports.

The datagram protocols (ncadg_ipx, ncadg_ip_udp) have the following limitations:

Only the ncacn_spx and ncacn_ip_tcp protocols support cancels. For all other protocols, the cancel routines will return RPC_S_OK, but there will be no effect. Specifically: RpcTestCancel, RpcMgmtSetCancelTimeout, and RpcCancelThread are only supported on Windows NT platforms; all other platforms return RPC_S_CANNOT_SUPPORT.

The function RpcBindingSetAuthInfo does not accept the value RPC_C_AUTHN_DEFAULT.

To use the RpcBindingSetAuthInfo routine and, in particular, when using MS-DOS authentication in this version of RPC, note this information:

For MS-DOS, you cannot pass NULL because there is no way for RPC to determine the current user's logon information. However, either a structure or NULL is acceptable for Windows versions 3.x and Windows NT.

When using authenticated RPC on a system composed of Novell NetWare and Windows version 3.x (not Windows for Workgroups), you must run the optional NETBIOS.EXE program before starting Windows.

The 16-bit SDK cannot be installed on a Windows NT computer unless the current user is an administrator.

Supported Platforms for Runtime APIs

The following function is supported only by 16-bit Windows 3.x platforms:

RpcWinSetYieldInfo

The following functions are supported only by 32-bit Windows NT platforms:

DceErrorInqTest RpcBindingInqAuthClient RpcBindingServerFromClient RpcCancelThread RpcEpRegister RpcEpUnregister RpcIfIdVectorFree RpcImpersonateClient RpcNetworkInqProtseqs RpcObjectInqType RpcObjectSetInqFn RpcObjectSetType RpcProtseqVectorFree RpcRevertToSelf RpcServerInqBindings RpcServerInqIf RpcServerListen RpcServerRegisterAuthInfo RpcServerRegisterIf RpcServerUnregisterIf RpcServerUse*Protseq* RpcMgmtInqIfIds RpcMgmtInqStats RpcMgmtIsServerListening RpcMgmtInqServerPrincName RpcMgmtSetAuthorizationFn RpcMgmtSetCancelTimeout RpcMgmtSetServerStackSize RpcMgmtStatsVectorFree RpcMgmtStopServerListening RpcMgmtWaitServerListen RpcMgmtEnableIdleCleanup RpcMgmtEpElt* RpcMgmtEpUnregister RpcNsBindingExport RpcNsBindingUnexport RpcTestCancel

All other runtime functions are supported on Windows NT, Windows 3.x, and MS-DOS platforms.

REFERENCES

RPCREAD.ME in \MSTOOLS\SAMPLES\RPC in Win32SDK for Windows NT 3.5 on MSDN.