PRB: Miniport Driver Fails Using Certain ScsiPort APIsID: Q160667
|
When you attempt to write a program or device driver that calls the following APIs, you may encounter the following errors:
Specifically, miniport drivers written to use these APIs may fail to load.ScsiPortReadRegisterUshort()
ScsiPortReadRegisterULong()
These APIs are documented as being exported by SCSIPORT.PDR. However, due to a problem in SCSIPORT.PDR, these APIs are not correctly exported.
This issue is resolved by the following updated file for Windows 95, and later versions of this file:
SCSIPORT.PDR version 4.00.951 dated 10/26/95 23,165 bytes
Microsoft has confirmed this to be a problem in Microsoft Windows 95. An
update to address this problem is now available, but is not fully
regression tested and should be applied only to computers experiencing
this specific problem. Unless you are severely impacted by this specific
problem, Microsoft does not recommend implementing this update at this
time. Contact Microsoft Technical Support for additional information about
the availability of this update.
This issue is resolved in Microsoft Windows 98.
For additional information about issues resolved by updates to this component, please see the following article in the Microsoft Knowledge Base:
Q155729 SCSI Devices May Not Be Enumerated Correctly
Q161020 Implementing Windows 95 Updates
Additional query words: 1.00 Windows
Keywords : kbhw win95
Version : WINDOWS:95
Platform : WINDOWS
Issue type : kbprb
Last Reviewed: July 6, 1999