ID: Q126129
1.00 3.10 3.50 WINDOWS kbinterop
The information in this article applies to:
When you install IntelliType software under Windows NT version 3.1 or 3.5, the following error appears:
Unable to show Program Manager group: 'Microsoft Input Devices'
When you choose OK, the following message appears:
Setup failed! Contact Microsoft Produce Support Services for help.
This problem occurs when you have 40 common Program Manager groups, and the IntelliType software attempts to add one more common group. Windows NT Program Manager does not support more than 40 common groups and 40 personal groups.
To work around this problem:
-or-
-or-
Microsoft has confirmed this to be a problem in IntelliType version 1.0. We are researching this problem and will post new information here in the Microsoft Knowledge Base as it becomes available.
KBCategory: kbinterop KBSubcategory: nthw ntinterop Additional reference words: prodnt 3.10 3.50 1.00 hardware
Keywords : NTInterop nthw
Version : 1.00 3.10 3.50
Platform : WINDOWS
Last Reviewed: September 10, 1996