Error 234 When Using NET VIEW in Windows for Workgroups 3.11
ID: Q127764
The information in this article applies to:
- Microsoft Windows NT operating system version 3.1
- Microsoft Windows NT Advanced Server version 3.1
- Microsoft Windows NT Workstation versions 3.5, 3.51
- Microsoft Windows NT Server versions 3.5, 3.51
- Microsoft Windows NT Workstation version 4.0
- Microsoft Windows NT Server version 4.0
- Microsoft Windows for Workgroups version 3.11
SYMPTOMS
When you run NET VIEW from a Windows for Workgroups version 3.11 client
system to view the shares on a Windows NT computer, the following error
message appears:
Error 234
If you attempt a similar operation in Windows for Workgroups File Manager
by selecting a Windows NT computer, the following error message appears:
An internal Lanman error has occurred.
CAUSE
There may be a corrupt share on the Windows NT computer.
RESOLUTION
To correct this problem, try one or more of the following steps:
- Disconnect from all shares on the Windows NT computer (including hidden
shares such as c$ and ipc$) and then reestablish the connections.
- If long share names are being used for either file shares or printer
shares, try renaming the share to contain no more than 12 characters.
- Delete all the shares on the server and then recreate them.
Additional query words: prodnt 3.10 3.50 3.11 wfw wfwg
Keywords : NTInterop
Version : 3.10 3.11 3.50
Platform : WINDOWS
Last Reviewed: May 19, 1997