Error 33 on Alternate RPC CallsLast reviewed: September 9, 1996Article ID: Q129148 |
The information in this article applies to:
SYMPTOMSEvery other RPC call fails when RPC applications are running on Windows and Windows for Workgroup clients. If the failed RPC call is issued a second time, it completes successfully.
CAUSESome DCE compliant RPC servers shutdown the RPC connection after a period of inactivity. The 16-bit Windows RPC client does not respond to the shutdown request. This prevents the client from cleanly closing the connection to the RPC server. After an extended period of time, the RPC server closes the connection even if the 16-bit RPC client does not respond.
STATUSMicrosoft has confirmed this to be a problem in the RPC16C3.DLL file that ships with Windows NT version 3.5 SDK. A fix to this problem is in development, but has not been regression-tested and may be destabilizing in production environments. Microsoft does not recommend implementing this fix at this time. Contact Microsoft Product Support Services for more information on the availability of this fix.
|
KBCategory: kbnetwork
© 1998 Microsoft Corporation. All rights reserved. Terms of Use. |