Premature UPS Service Termination, Server Service PausedLast reviewed: May 9, 1997Article ID: Q103501 |
The information in this article applies to:
SYMPTOMSA power break occurs and the UPS (uninterruptable power supply) service maintains the system for a short time. The UPS service times-out and terminates before power returns or the system can be prepared for shutdown. It also pauses the Windows NT Server service. -or- A power break occurs and power is restored before the battery runs out. However, the UPS service times-out and terminates, leaving the system vulnerable to the next power break (also pausing the Server service). In both cases, the following events are logged:
Event ID: 258 Source: UPS Type: Error Error: The description for Event ID (258) in Source (UPS) could not be found. Event ID: 3230 Source: UPS Type: Warning Error: A power failure was detected at the server. CAUSEYour UPS device does not have a low battery signal (or it was disabled) and, instead of handling this properly, the UPS service terminates prematurely. The problem is in the UPS service.
RESOLUTIONIn either case, you should contact Microsoft Product Support Services for an updated UPS.EXE file. If your UPS and Server services are currently paused, restart them by choosing Services from Control Panel.
STATUSMicrosoft has confirmed this to be a problem in Windows NT and Windows NT Advanced Server version 3.1. This problem was corrected in the latest U.S. Service Pack for Windows NT and Windows NT Advanced Server version 3.1. For information on obtaining the Service Pack, query on the following word in the Microsoft Knowledge Base (without the spaces):
S E R V P A C K |
Additional query words: prodnt times out