Server Manager Cannot Find DC with TCP/IP and ELNK3Last reviewed: May 14, 1997Article ID: Q112826 |
The information in this article applies to:
SYMPTOMSWhen you use the 3Com EtherLink III adapter model 3c509 or the 3c579 network interface card with TCP/IP as the only protocol, the following error message appears when you open Server Manager locally on the domain controller (DC):
Cannot find the primary DC for <domain>. You may administer this domain, but certain domain-wide operations will be disabled. CAUSEWindows NT streams-based TCP/IP does not set the lookahead buffer size. The default lookahead buffer size that the ELNK3 driver sets is too small. This only effects loopback packets.
WORKAROUNDBind NetBEUI to the ELNK3 driver. NetBEUI sets the lookahead buffer size properly.
STATUSMicrosoft has confirmed this to be a problem in Windows NT and Windows NT Advanced Server version 3.1. This problem has been corrected in the latest U.S. Service Pack for Windows NT and Windows NT Advanced Server version 3.1. For information on obtaining the Service Pack, query on the following word in the Microsoft Knowledge Base (without the spaces):
S E R V P A C K |
Additional query words: prodnt ntas
© 1998 Microsoft Corporation. All rights reserved. Terms of Use. |