DOCUMENT:Q238752 23-AUG-2001 [odbc] TITLE :PRB: SQLConfigDatasource Allows PageTimeout Value of 0 PRODUCT :Open Database Connectivity (ODBC) PROD/VER::3.0,3.5,3.6,4.0 OPER/SYS: KEYWORDS:kbODBC kbODBC300 kbODBC350 kbODBC351 kbGrpDSVCDB kbGrpDSMDAC kbDSupport kbMDAC260 ====================================================================== ------------------------------------------------------------------------------- The information in this article applies to: - Microsoft ODBC Driver for Access, versions 3.0, 3.5, 3.6, 4.0 ------------------------------------------------------------------------------- SYMPTOMS ======== The ODBC API call, SQLConfigDataSource(), provides the application developer a means to programmatically create a Datasource Name (DSN) for the ODBC "Microsoft Access Driver (*.mdb)." The SQLConfigDataSource() function can create a registry entry for PageTimeout that allows the value of 0. When the DSN is created in this manner and is reviewed in the ODBC Administrator, the following error message is displayed when the button is clicked: ODBC Microsoft Access Setup - Invalid page timeout value. CAUSE ===== A PageTimeout value of 0 or less is not valid for this driver property. RESOLUTION ========== Ensure that the PageTimeout value is set to something greater than 0 when using the SQLConfigDataSource() function in the ODBC API. MORE INFORMATION ================ Steps to Reproduce Problem -------------------------- 1. Use the following code to create a DSN that has a PageTimeout value of 0: #include #include #include int main(int argc, char* argv[]) { BOOL rc; char szDriver[] = "Microsoft Access Driver (*.mdb)\0\0"; rc = SQLConfigDataSource( NULL, ODBC_ADD_DSN, szDriver, (LPCSTR)"DSN=TestDSN\0" "DBQ=C:\\db1.mdb\0" "DRIVER=C:\\WINNT\\System32\\odbcjt32.dll\0" "DRIVERID=25\0" "PAGETIMEOUT=0\0" "FIL=MS Access\0" "THREADS=3\0" "DESCRIPTION=Testing Driver\0" "UID=sa\0" "IMPLICITCOMMITSYNC=Yes\0" "MAXBUFFERSIZE=2048\0" "USERCOMMITSYNC=Yes\0" " General\0\0"); return 0; } 2. Click ODBC Administrator. 3. Select the DSN you created, then click Configure. 4. Click Advanced to see the PageTimeout value. 5. Press OK. Additional query words: SQLConfigDataSource PageTimeOut ====================================================================== Keywords : kbODBC kbODBC300 kbODBC350 kbODBC351 kbGrpDSVCDB kbGrpDSMDAC kbDSupport kbMDAC260 Technology : kbAudDeveloper kbAccessSearch kbODBCSearch kbODBCAccess300 kbODBCAccess350 kbODBCAccess360 kbODBCAccess400 Version : :3.0,3.5,3.6,4.0 Issue type : kbprb ============================================================================= THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY. Copyright Microsoft Corporation 2001.