ACC: Save Password Check Box Dimmed When Linking ODBC TablesID: Q164003
|
Advanced: Requires expert coding, interoperability, and multiuser skills.
You are unable to save the Login ID and Password locally when you link a
table from an ODBC data source because the "Save password" check box is
dimmed in the Link Tables dialog box.
There are two possible causes:
Config nValue
------ ------
101 0
Config nValue
------ ------
101 1
HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows\CurrentVersion
\Policies\Network\DisablePwdCaching
If you are administering an SQL database that uses Microsoft Access as a
front end, you can create a table in your SQL database named MSysConf to
help control communication between the two applications. The MSysConf table
has two potential functions:
For more information about using the MSysConf table to prevent the storage
of Login IDs and Passwords locally, please see the following article in the
Microsoft Knowledge Base:
Q101084 ACC: Storing SQL Database Login IDs and Passwords Locally
For more information about the MSysConf table, search the Help Index for
"MSysConf table."
For more information about disabling password caching using the Policy
Editor in Microsoft Windows 95, please see the following article in the
Microsoft Knowledge Base:
Q142233 No Password Prompt After Network Adapter Is Detected
Additional query words: attach
Keywords : kbusage OdbcMsys