XADM: Invalid Parameters When Using X.121 Field in X.400 AddressID: Q156722
|
This problem occurs when you send a message from Microsoft Exchange to a
fax by means of an X.400 address (form 1 variant 3) such as the following:
C=FR;A=ATLAS;X.121=93312345678
Sending to X.121=93312345678 is correctly handled by remote systems.diagnostics = 11 : invalid parameters.
In the first case, the P2 O/R name is incorrectly coded; it contains only C=FR;A=ATLAS. The X.121 field is missing.
Microsoft has confirmed this to be a problem in Microsoft Exchange Server version 4.0. This problem was corrected in the latest Microsoft Exchange 4.0 U.S. Service Pack. For information on obtaining the service pack, query on the following word in the Microsoft Knowledge Base (without the spaces):
S E R V P A C K
Additional query words:
Keywords : kbusage kbbug4.00 kbfix4.00.sp4 XADM
Version : winnt:4.0
Platform : winnt
Issue type : kbbug