XADM: System Attendant Crash During GWART CalculationID: Q140936
|
The Microsoft Exchange System Attendant starts to use 90-100% of the CPU time and then crashes with the following error message:
Following this, a Dr Watson log is generated:Unexpected function: function "SC RUN RideX" exception: 0xc0000005 location: 0xbdb5781D occurred.
Application MAD.DBG Generated an Application Error
Exception Error C0000005 at address 0xbdb5781D.
The problem is caused when a Microsoft Exchange Gateway Address Routing Table (GWART) containing a potential circular route, is imported from one Microsoft Exchange Server into a second Microsoft Exchange Server. When this second Microsoft Exchange Server attempts to regenerate it's GWART to remove the circular route, it crashes.
Microsoft has confirmed this to be a problem in Microsoft Exchange Server version 4.0. This problem was corrected in Microsoft Exchange Server 4.0 U.S. Service Pack 2. For information on obtaining the service pack, query on the following word in the Microsoft Knowledge Base (without the spaces):
S E R V P A C K
Additional query words: MAD
Keywords : kbusage kbbug4.00 kbfix4.00.sp2 XADM
Version : 4.0
Platform : WINDOWS
Issue type :
Last Reviewed: March 11, 1999