"PMAdmin add dbserver /maxconnection" Does Not WorkID: Q188363
|
"PMAdmin add dbserver /maxconnection" always sets maxconnection to 0. This renders the partition unusable until the Maximum Connections can be reset.
To resolve this problem, apply the latest Site Server 3.0 service pack.
To work around this problem, use the Microsoft Management Console (MMC) to set the Maximum Connections. To modify the Maximum Connections in the MMC, in the left pane, right-click on the LDAP service of your Membership Instance and choose Properties. From the LDAP Properties page, select the Directory Properties tab. In the Container Partition drop-down box, select the partition you want to edit. From the list of databases, select the one you want to change, and click Edit. Edit the Maximum Connections in the Database Server Properties box.
Microsoft has confirmed this to be a problem in Site Server version 3.0. This problem was corrected in the latest Microsoft Site Server version 3.0 U.S. Service Pack. For information about obtaining the service pack, query on the following word in the Microsoft Knowledge Base (without the spaces):
S E R V P A C K
Additional query words: sp
Keywords : Ss3Sp1fix
Version : winnt:3.0
Platform : winnt
Issue type : kbbug
Last Reviewed: July 26, 1999