CRS: Web Administrator Dialog Boxes Incorrectly Sized When Viewed with Internet Explorer Version 4.0

ID: Q179290


The information in this article applies to:


SYMPTOMS

When you view the Content Replication Server (CRS) version 2.0 Web Administrator[ASCII 146]s dialog boxes in Microsoft Internet Explorer (IE) version 4.0, the boxes are incorrectly sized. Also, the OK, Cancel, and Help buttons are not visible, and the dialog box window is not resizable.


CAUSE

The dialog box sizes are hard coded in the Ossa Web Administrator, and IE 4.0 puts more vertical white space in tables in the dialog boxes than IE 3.0 does.


STATUS

Microsoft has confirmed this to be a problem in Microsoft Commercial Internet System version 1.0 and Site Server version 2.0. This problem has been corrected in the latest U.S. Service Pack for Site Server 2.0 Service Pack 1. For information on obtaining the Service Pack, query on the following word in the Microsoft Knowledge Base (without the spaces):

S E R V P A C K

Additional query words:


Keywords          : kbbug2.00 
Version           : WINNT:1.0,2.0
Platform          : winnt 
Issue type        : kbbug 

Last Reviewed: July 20, 1999