How to Reinstall Proxy Server 2.0 Performance Monitor Counters

ID: Q226543


The information in this article applies to:


SUMMARY

This article provides detailed instructions for reinstalling or removing and reinstalling the Proxy Server 2.0 Performance Monitor Counters.


MORE INFORMATION

Three files are required to install Performance Monitor Counters for NTOP services. One file is a .ini file that contains the installation instructions for the counters, another is a .h file that contains the symbolic and offset information for the counters, and the third file is the .dll file that maintains the counters statistics. These three files must reside in the %windir%\system32 directory before they can be installed for use with Performance Monitor.

If the main Performance Monitor data files (Perfc009.dat and Perfh009.dat) have become corrupted, you can use the following article to correct the problem:

Q127207 Missing Objects and Counters in Performance Monitor
The following table provides a list of all Proxy Server 2.0 Performance Monitor Objects, their corresponding .ini, .h, and .dll files, and their registry key name.

Object name .ini file name .h file name .dll file name Services registry key name
Winsock Proxy Server Wspperf.ini Wspperf.h Wspperf.dll WSPSrv
Web Proxy Server Service W3pctrs.ini W3pctrs.h Mspmon.dll W3proxy
Packet Filtering Pfctrs.ini Pfctrs.h Mspmon.dll Mspadmin
Web Proxy Server Cache Cachctrs.ini Cachctrs.h Mspmon.dll W3pcache


Use the following instructions to install or reinstall Performance Monitor Counters for Proxy Server 2.0 services:
  1. To install an object's counters, the object's .ini, .h, and .dll files must reside in the %windir%\system32 directory. Using the above table determine which .ini, .h, and .dll files you need for the object you want to install. Determine if the .ini, .h, and .dll files are in the %windir%\system32 directory. If they are not, you can copy the files to the %windir%\system32 directory from the Microsoft Proxy Server 2.0 compact disc. The .ini and .h files can be found in the I386\Perfctrs or Alpha\Perfctrs directory and the .dll files are in the I386 or Alpha directory.


  2. Open a Command Prompt and change the directory to %windir%\system32.


  3. Type the following:
    lodctr <.INI File Name for Object to Install>
    If you receive the following message:
    Counters for <OBJECT NAME> are already installed
    Unable to update the system registry
    type the following:
    unlodctr <Services Registry Key Name>
    and re-type:
    lodctr <.INI File Name for Object to Install>


  4. Repeat Steps 1 through 3 for each object that you want to install Performance Monitor Counters for.


Additional query words:


Keywords          : 
Version           : winnt:2.0
Platform          : winnt 
Issue type        : kbhowto 

Last Reviewed: April 29, 1999