ID: Q180255
The information in this article applies to:
When you install Proxy Server 2.0 with the documentation and later remove the documentation through Setup, or if you install Proxy Server 2.0 without documentation and later add the documentation through Setup, the proxy services will fail to start.
After you restart the server system, the following two messages appear on the logon screen:
- mspadmin.exe - DLL Initialization Failed
Initialization of the dynamic link library C:\WINNT\system32\MSPHLPR.dll
failed. The process is termination abnormally.
- wspsrv.exe - DLL Initialization Failed
Initialization of the dynamic link library C:\WINNT\system32\MSPHLPR.dll
failed. The process is termination abnormally.
Service Control Manager adds the following two event log error entries:
The Microsoft Proxy Server Administration service failed to start due to
the following error: The service did not respond to the start or control
request in a timely fashion.
Timeout (120000 milliseconds) waiting for service to connect.
The Proxy Server Setup program deletes the Mspclnt.ini file in the Proxy Servers Client folder when the Proxy Server documentation is either installed or removed. This missing Mspclnt.ini file causes the proxy services to fail starting.
To work around the problem, use of the following procedures:
Microsoft has confirmed this to be a problem in Proxy Server version 2.0. We are researching this problem and will post new information here in the Microsoft Knowledge Base as it becomes available.
Keywords : pxssetup
Version : 2.0
Platform : winnt
Issue type : kbbug
Solution Type : kbnofix
Last Reviewed: March 7, 1998