SNA Server Rejects Host's BIND Response when the Primary Session Level Pacing Receive Window Size Is ZeroID: Q223373
|
After you upgrade your VTAM version to 4.4 on the host, SNA Server starts rejecting the host's BIND responses with an UNBIND(06):
In the Windows NT application log the following event may be seen:Invalid session parameters:
The BIND negotiation has failed because the primary half-session cannot
support parameters specified by the secondary.
Event ID: 22
Description: APPC session activation failure:
BIND negotiated parameters unacceptable, Sense data = 10050000.
SNA Server checks the BIND response pacing parameters to ensure that the PRIMARY RECEIVE WINDOW FIELD SIZE is equal to THE SECONDARY SEND WINDOW SIZE. If this is not true, then the BIND response is rejected.
A supported fix that corrects this problem is now available from Microsoft, but
it has not been fully regression tested and should be applied only to systems
experiencing this specific problem. If you are not severely affected by this
specific problem, Microsoft recommends that you wait for the next Microsoft SNA Server version 4.0 service pack
that contains this fix.
To resolve this problem immediately, contact Microsoft Product Support Services
to obtain the fix. For a complete list of Microsoft Product Support Services
phone numbers and information on support costs, please go to the following
address on the World Wide Web:
http://www.microsoft.com/support/supportnet/overview/overview.aspThe English version of this fix should have the following file attributes or later:
File name | Date | Time |
---|---|---|
Snaservr.exe | 3/12/99 | 13:34 |
Trcservr.exe | 3/12/99 | 13:34 |
Q154871 Determining If You Are Eligible for No-Charge Technical Support
To workaround this problem, change the configuration files on the host that are responsible for coding the BIND image so that the BIND RSP ensures the PRIMARY RCV WINDOW SIZE = THE SECONDARY SEND WINDOW SIZE rather then making byte 13 equal zero.
Also note that IBM has produced a PTF and an APAR that addresses this problem for
OS390 V2.5 and VTAM 4.4. For information about obtaining this PTF and APAR, please contact IBM Technical Support or visit IBM's Web site at http://www.ibm.com.
Microsoft has confirmed this to be a problem in Microsoft SNA Server version 4.0 Service Pack 2.
The IBM Formats Reference Manual indicates the following for byte 13 of a BIND response:
Q65416 Hardware and Software Third-Party Vendor Contact List, A-K
Q60781 Hardware and Software Third-Party Vendor Contact List, L-P
Q60782 Hardware and Software Third-Party Vendor Contact List, Q-Z
Additional query words: BIND PACING
Keywords :
Version : WINDOWS:4.0SP2
Platform : WINDOWS
Issue type : kbbug
Last Reviewed: June 28, 1999