BUG: Client Network Utility Allows Invalid IPX Port Address Format

ID: Q199000


The information in this article applies to:

BUG #: 48157 (SQLBUG_70)

SYMPTOMS

When using the Client Network Utility to add a new client configuration entry, which uses the NWLink IPX/SPX network library, an invalid port address format is allowed.


CAUSE

Format error checking is not performed in the Client Network Utility.


STATUS

Microsoft has confirmed this to be a problem in SQL Server version 7.0.


MORE INFORMATION

For NWLink IPX/SPX, the port address should start with '0x'.

Additional query words: NWLink IPX/SPX


Keywords          : kbSQLServ700 kbSQLServ700bug 
Version           : winnt:7.0
Platform          : winnt 
Issue type        : kbbug 

Last Reviewed: April 27, 1999