BUG: Rebuild Master Fails When Setup Cannot Connect to SQL ServerID: Q238309
|
On a SQL Server 6.5 server that is configured to listen on the NWLink IPX/SPX network library, rebuild master may fail with the following error:
After getting the error, SQL Server may fail to start. The following entry is logged in the errorlog:The master database could not be successfully rebuilt. Setup could not connect to the SQL Server.
97/06/27 09:17:26.35 spid1 server is unnamed 97/06/27 09:17:26.37 spid1 Error: 3405, Severity: 10, State: 3 97/06/27 09:17:26.37 spid1 Recovery dbid 3 ckpt (131,18) oldest = tran=3D(131,0) 97/06/27 09:17:26.37 spid1 Clearing temp db 97/06/27 09:17:26.37 spid1 Error: 941, Severity: 14, State: 1 97/06/27 09:17:26.37 kernel Failed to create temp db
Remove NWLink IPX/SPX network support by running the SQL Setup and selecting "Change Network support". Rebuild the master database, then enable IPX/SPX support.
Microsoft has confirmed this to be a problem in SQL Server version 6.5.
Additional query words:
Keywords : SSrvInst kbbug6.50 kbSQLServ650bug
Version : winnt:6.5
Platform : winnt
Issue type : kbbug