PRB: Repl Logreader Fails on Remote Distributor after Cluster Failover

ID: Q233338


The information in this article applies to:


SYMPTOMS

When a remote distributor is located on a cluster server, the logreader may fail to run after a failover if the logreader was actively reading at the time of the node failure. The following error occurs:

The process could not execute 'sp_repldone/sp_replcounters' on '<publisher server name>'


CAUSE

An orphaned Server Process ID (SPID) remains on the publisher after the failover. The logreader recognizes this SPID as another logreader on that database and fails to start.


WORKAROUND

Here are two workarounds:

Additional query words: replication


Keywords          : kbSQLServ700 
Version           : winnt:7.0
Platform          : winnt 
Issue type        : kbprb 

Last Reviewed: July 30, 1999