SMS: Internal Error in Admin Console When Refreshing Pkg. StatusID: Q234916
|
On sites with a large number of packages, the Microsoft Management Console (MMC) Administrator Console may display a message box titled "Internal Error" when you attempt to open or refresh one of the nodes under Package Status. The message box text is:
The message box may take a long time to come up. If you press the More Information button on the message box, it usually looks like the following:An error occurred during your last operation. Please shut down the Systems Management Server Administrator's Console and restart it. For debugging information, press the More Information button.
_com_error exception in MMC Admin UI!
Description: Factory Enumeration Failure
HRESULT: 0xEEEE0001
File: E:\OPAL\mmcadminui\Support\SMS_NMGR\NMGR_NodeData.cpp
Line: 221
<><><><><><><><><><><><><><><><><><><><><><><><><><><><><><><><><><><>
Description: XXXXX
In the text above, XXXXX is usually something like:
SQL Err>> DBProcess is DEAD or not enabled.
SQL Err>> Invalid operator for datatype op: UNKNOWN TOKEN
Or some other text indicating that there is a problem with the SQL Server.
To resolve this problem, obtain the latest service pack for Systems Management Server 2.0. For additional information, please see the following article in the
Microsoft Knowledge Base:
Q236325 SMS: How to Obtain the Latest Systems Management Server 2.0 Service Pack
Microsoft has confirmed this to be a problem in Systems Management Server 2.0. This problem was first corrected in Systems Management Server 2.0 Service Pack Service Pack 1.
Additional query words: prodsms hang hangs hung admin timout
Keywords : kbMMC kbSMS200 kbSMS200bug kbSMS120 kbSMS120bug kbSMSAdmin
Version : winnt:1.2,2.0
Platform : winnt
Issue type : kbbug